{"id":"fa471111-a606-4cf6-a0af-630eabd46b92","slug":"clawhub-zw008-iaiops-energy","name":"iaiops-energy","description":"Vendor-neutral, governed, READ-ONLY energy/substation telecontrol data tap — the energy edition (变电/电力) of Industrial-AIOps. Monitor-direction telemetry over IEC 60870-5-104 (IEC-104: RTU link status, general interrogation, single monitored-point reads by IOA — 遥测/遥信), DNP3 / IEEE 1815 (outstation link status, Class 0/1/2/3 integrity poll), and IEC 61850 MMS (IED logical-device directory, model browse, data-attribute reads) — plus the base cross-protocol brain (dataflow diagnosis, alarm bad-actors, data-quality scorecards, OEE, asset inventory, compliance self-assessment) mounted on the same server. Use when the task names IEC 60870-5-104 / IEC-104 / 104规约, DNP3 / IEEE 1815 / outstation, IEC 61850 / MMS / IED / GOOSE (GOOSE and Sampled Values are NOT supported — MMS reads only), a substation / 变电站 / RTU / SCADA gateway / telecontrol front-end, energy / power / utility SCADA telemetry, or 遥测遥信 / 电力监控. Routes to the iaiops-energy MCP server. Monitor-only by design: no control/operate (CROB, setpoints, select-before-operate, IEC-104 command ASDUs) is exposed. Do NOT use for factory/building/process protocols (OPC-UA, Modbus, S7, BACnet, MQTT …) — those live in the base iaiops server — nor for IT/network gear, Kubernetes, hypervisors, or backups.","canonicalUrl":"https://www.xpersona.co/agent/clawhub-zw008-iaiops-energy","sourceUrl":"https://clawhub.ai/zw008/iaiops-energy","homepage":"https://clawhub.ai/zw008/skills/iaiops-energy","source":"CLAWHUB","vendor":{"slug":"clawhub","label":"Clawhub","url":"https://clawhub.ai/zw008/skills/iaiops-energy"},"protocols":["OPENCLEW"],"capabilities":[],"trustScore":null,"trustConfidence":"unknown","artifactCount":0,"benchmarkCount":0,"lastRelease":"0.1.12","freshnessAt":"2026-10-11T16:51:15.983Z","freshnessLabel":"Oct 11, 2026","securityReviewed":true,"openapiReady":false,"stats":[{"label":"Trust score","value":"Unknown"},{"label":"Compatibility","value":"OpenClaw"},{"label":"Freshness","value":"Oct 11, 2026"},{"label":"Vendor","value":"Clawhub"},{"label":"Artifacts","value":"0"},{"label":"Benchmarks","value":"0"},{"label":"Last release","value":"0.1.12"}],"factsPreview":[{"factKey":"vendor","category":"vendor","label":"Vendor","value":"Clawhub","href":"https://clawhub.ai/zw008/skills/iaiops-energy","sourceUrl":"https://clawhub.ai/zw008/skills/iaiops-energy","sourceType":"profile","confidence":"medium","observedAt":"2026-10-11T16:51:15.998Z","isPublic":true},{"factKey":"protocols","category":"compatibility","label":"Protocol compatibility","value":"OpenClaw","href":"https://www.xpersona.co/api/v1/agents/clawhub-zw008-iaiops-energy/contract","sourceUrl":"https://www.xpersona.co/api/v1/agents/clawhub-zw008-iaiops-energy/contract","sourceType":"contract","confidence":"medium","observedAt":"2026-10-11T16:51:15.998Z","isPublic":true},{"factKey":"traction","category":"adoption","label":"Adoption signal","value":"1K downloads","href":"https://clawhub.ai/zw008/iaiops-energy","sourceUrl":"https://clawhub.ai/zw008/iaiops-energy","sourceType":"profile","confidence":"medium","observedAt":"2026-10-11T16:51:15.998Z","isPublic":true},{"factKey":"latest_release","category":"release","label":"Latest release","value":"0.1.12","href":"https://clawhub.ai/zw008/iaiops-energy","sourceUrl":"https://clawhub.ai/zw008/iaiops-energy","sourceType":"release","confidence":"medium","observedAt":"2026-08-02T13:57:32.970Z","isPublic":true},{"factKey":"handshake_status","category":"security","label":"Handshake status","value":"UNKNOWN","href":"https://www.xpersona.co/api/v1/agents/clawhub-zw008-iaiops-energy/trust","sourceUrl":"https://www.xpersona.co/api/v1/agents/clawhub-zw008-iaiops-energy/trust","sourceType":"trust","confidence":"medium","observedAt":null,"isPublic":true}],"highlights":["1K downloads","Trust evidence available"],"agentCard":{"name":"iaiops-energy","description":"Vendor-neutral, governed, READ-ONLY energy/substation telecontrol data tap — the energy edition (变电/电力) of Industrial-AIOps. Monitor-direction telemetry over IEC 60870-5-104 (IEC-104: RTU link status, general interrogation, single monitored-point reads by IOA — 遥测/遥信), DNP3 / IEEE 1815 (outstation link status, Class 0/1/2/3 integrity poll), and IEC 61850 MMS (IED logical-device directory, model browse, data-attribute reads) — plus the base cross-protocol brain (dataflow diagnosis, alarm bad-actors, data-quality scorecards, OEE, asset inventory, compliance self-assessment) mounted on the same server. Use when the task names IEC 60870-5-104 / IEC-104 / 104规约, DNP3 / IEEE 1815 / outstation, IEC 61850 / MMS / IED / GOOSE (GOOSE and Sampled Values are NOT supported — MMS reads only), a substation / 变电站 / RTU / SCADA gateway / telecontrol front-end, energy / power / utility SCADA telemetry, or 遥测遥信 / 电力监控. Routes to the iaiops-energy MCP server. Monitor-only by design: no control/operate (CROB, setpoints, select-before-operate, IEC-104 command ASDUs) is exposed. Do NOT use for factory/building/process protocols (OPC-UA, Modbus, S7, BACnet, MQTT …) — those live in the base iaiops server — nor for IT/network gear, Kubernetes, hypervisors, or backups.","source":"CLAWHUB","sourceId":"clawhub:s171xgnmqse0nqvgqvqnaq5f9183kyre:iaiops-energy","homepage":"https://clawhub.ai/zw008/skills/iaiops-energy","repository":"https://clawhub.ai/zw008/iaiops-energy","documentation":"https://www.xpersona.co/agent/clawhub-zw008-iaiops-energy","protocols":["OPENCLEW"],"examples":[{"kind":"example","language":"bash","snippet":"pip install 'iaiops-energy[energy]'      # all three protocols\npip install 'iaiops-energy[iec104]'      # or per-protocol extras:\npip install 'iaiops-energy[dnp3]'        #   [iec104] / [dnp3] / [iec61850]\niaiops-energy-mcp                        # brain + energy tools over stdio"},{"kind":"example","language":"json","snippet":"{\n  \"mcpServers\": {\n    \"iaiops-energy\": {\n      \"command\": \"iaiops-energy-mcp\",\n      \"env\": {\n        \"IAIOPS_CONFIG\": \"/etc/iaiops/config.yaml\",\n        \"IAIOPS_MASTER_PASSWORD\": \"<from your secret manager>\"\n      }\n    }\n  }\n}"}]}}